Tel
0577-62795555
News & Topics at Hont Cable Ties
Nov , 26-2021
Mar 25th Shows New Historical High Prices For NYLON 66Jul , 19-2021
UV Black Cable TieMaximum electrical rating of insulated ring terminal: 600volts
Maximum temperature of insulated ring: 75℃
Terminal Body of insulated ring lugs: The terminal body of ring type insulated cable lugs is made of Brass or Copper
Plating of ring terminal insulated: Tin plated
Insulation material of terminal ring connectors: vinyl (PVC)
We also provide some other prodects with some alike functions, like insulated flag terminal crimping tool and female disconnect wire connectors.
Item NO. | UNC | screw dia. | Dimension | Color | |||||
d2(mm) | B(mm) | L(mm) | F(mm) | H(mm) | D φ(mm) | ||||
Cable size:0.5~1.5mm2(A.W.G.22~16) max current:Imax=19A thickness:0.75mm | |||||||||
RV1.25-3 | #4 | 3.2 | 5.7 | 17.8 | 4.95 | 10 | 4.3 | 0.5~1.5mm² (22-16):Imax=19A | Red |
RVS1.25-3.5 | #6 | 3.7 | 5.7 | 17.8 | 4.95 | ||||
RVM1.25-3.5 | #6 | 3.7 | 6.6 | 20.1 | 6.3 | ||||
RVL1.25-3.5 | #6 | 3.7 | 8 | 21.5 | 7 | ||||
RVS1.25-4 | #8 | 4.3 | 6.6 | 20.1 | 6.3 | ||||
RVL1.25-4 | #8 | 4.3 | 8 | 21.5 | 7 | ||||
RV1.25-5 | #10 | 5.3 | 8 | 21.5 | 7 | ||||
RV1.25-6 | 1/4 | 6.5 | 11.6 | 27.5 | 11.1 | ||||
RV1.25-8 | 516 | 8.4 | 11.6 | 27.5 | 11.1 | ||||
RV1.25-10 | 3/8 | 10.5 | 13.6 | 31.6 | 13.9 | ||||
Cable size: 1.5~2.5mm2(A.W.G.16~14) max current:Imax=27A thickness:0.8mm | |||||||||
RV2-3 | #4 | 3.2 | 6.6 | 17.8 | 4.3 | 10 | 4.9 | 1.5~2.5mm² (16~14):Imax=27A | Blue |
RVS2-3.5 | #6 | 3.7 | 6.6 | 17.8 | 4.3 | ||||
RVM2-3.5 | #6 | 3.7 | 6.6 | 21 | 7 | ||||
RVL2-3.5 | #6 | 3.7 | 8.5 | 22.5 | 7.75 | ||||
RVS2-4 | #8 | 4.3 | 6.6 | 21 | 7 | ||||
RVL2-4 | #8 | 4.3 | 8.5 | 22.5 | 7.75 | ||||
RVS2-5 | #10 | 5.3 | 8.5 | 22.5 | 7.75 | ||||
RVL2-5 | #10 | 5.3 | 9.5 | 22.5 | 7.25 | ||||
RV2-6 | 1/4 | 6.5 | 12 | 27.6 | 11 | ||||
RV2-8 | 1/3 | 8.4 | 12 | 27.6 | 11 | ||||
RV2-10 | 3/8 | 10.5 | 13.6 | 30.2 | 13.9 | ||||
Cable size: 2.5~4mm2(A.W.G.14~12) max current:Imax=37A thickness:1.0mm | |||||||||
RV3.5-4 | #8 | 4.3 | 8 | 24.5 | 7.7 | 12.5 | 6.2 | 2.5~4mm² (14~12):Imax=37A | Black |
RVS3.5-5 | #10 | 5.3 | 8 | 24.5 | 7.7 | ||||
RVL3.5-5 | #10 | 5.3 | 12 | 27.9 | 7.7 | ||||
RV3.5-6 | 1/4 | 6.5 | 12 | 27.9 | 7.7 | ||||
Cable size: 4~6mm2(A.W.G.12~10) max current:Imax=18A thickness:1.0mm | |||||||||
RV5.5-3.5 | #6 | 3.7 | 7.2 | 21.4 | 5.9 | 12.5 | 6.7 | 4~6mm² (12~10) :Imax=48A | Yellow |
RVS5.5-4 | #8 | 4.3 | 7.2 | 21.5 | 5.9 | ||||
RVL5.5-4 | #8 | 4.3 | 9.5 | 25.5 | 8.3 | ||||
RV5.5-5 | #10 | 5.3 | 9.5 | 25.5 | 8.3 | ||||
RV5.5-6 | 1/4 | 6.5 | 12 | 31.5 | 13 | ||||
RV5.5-8 | 5/16 | 8.4 | 15 | 33.7 | 13.7 | ||||
RV5.5-10 | 3/8 | 10.5 | 15 | 33.7 | 13.7 | ||||
RV5.5-12 | 1/2 | 13 | 19.2 | 38.1 | 16 |
Vinyl/PVC Terminals:Vinyl/PVC terminals are electrical connectors covered in a layer of vinyl or polyvinyl chloride. They come in various sizes and shapes, making them versatile for different applications.
Electrical Wiring:
Ideal for connecting wires in electrical systems.
Resistant to moisture, chemicals, and abrasion.
Automotive Applications:
Widely used in vehicles for connecting electrical components.
PVC provides protection against harsh conditions.
Nylon Terminals:Nylon terminals are connectors made with nylon insulation. This material offers excellent durability and insulation properties.
Heavy-Duty Connections:
Suited for high-stress environments.
Commonly used in industrial settings and heavy machinery.
Moisture Resistance:
Nylon's resistance to moisture makes these terminals suitable for outdoor applications.
Prevents corrosion and ensures a secure connection.
Heat Shrink Terminals: Heat shrink terminals have a plastic outer layer that shrinks when heat is applied, creating a tight seal around the wire.
Sealing and Insulating:
Perfect for creating a watertight seal.
Provides insulation in areas with exposure to extreme temperatures.
Wire Protection:
Guards against abrasion and physical damage.
Commonly used in marine and automotive wiring.
Enhanced Safety:
The primary advantage of insulated ring terminals is safety.
The insulation layer provides a barrier, preventing accidental contact with exposed wires.
Reduces the risk of electrical shocks and short circuits.
Prevention of Short Circuits:
The insulation layer acts as a safeguard against short circuits.
Minimizes the chance of wires coming into contact with each other and causing electrical malfunctions.
Corrosion Resistance:
Insulated ring terminals often have coatings that resist corrosion.
Suitable for environments where moisture or harsh conditions could affect the connections.
Durability in Harsh Environments:
Designed to withstand challenging conditions.
Ideal for applications where the terminals may be exposed to extreme temperatures, chemicals, or vibrations.
Ease of Identification:
Insulation is often color-coded, aiding easy identification of wire sizes.
Facilitates organized and efficient installation, reducing the chances of errors.
Enhanced Safety:
Insulation layer provides a barrier, reducing the risk of electrical shocks and short circuits.
Ideal for applications where safety is a top priority.
Prevention of Short Circuits:
Acts as a safeguard against wires coming into contact, minimizing the risk of short circuits.
Offers added protection in environments prone to electrical malfunctions.
Corrosion Resistance:
Often coated to resist corrosion, making them suitable for harsh conditions.
Ideal for installations exposed to moisture or corrosive substances.
Ease of Identification:
Color-coded insulation aids in quick identification of wire sizes.
Facilitates organized installations, reducing the chances of errors.
Durability in Harsh Environments:
Designed to withstand challenging conditions, including extreme temperatures and vibrations.
Ensures longevity and reliability in diverse environments.
Cost-Effective:
Typically more budget-friendly compared to insulated counterparts.
Ideal for projects with tight budget constraints.
Simple Installation:
Straightforward installation process without dealing with insulation layers.
Quick and easy connections, making them suitable for simple applications.
Compact Design:
Non-insulated terminals are often more compact.
Useful in situations where space is limited.
Versatility:
Suitable for a broad range of applications where insulation may not be a critical factor.
Offers flexibility in less demanding environments.
Ring Shape:
As the name suggests, ring terminals have a circular shape with a hole in the center.
Designed to be secured to a terminal post or screw.
Secure Connection:
Offers a secure and stable connection.
Ideal for applications where vibration or movement is a consideration.
Versatility:
Available in various sizes to accommodate different wire gauges.
Versatile for a wide range of applications, from automotive to home wiring.
Ease of Use:
Easy to install by slipping the ring over a terminal post and securing it with a nut or screw.
Provides a reliable and long-lasting connection.
Flat, Forked Shape:
Spade terminals have a flat, forked shape resembling a spade.
The forked end is designed to be inserted under a screw or secured to a terminal.
Quick Connections:
Known for their ease of use and quick connections.
Suitable for applications where frequent disconnection is necessary.
Space Efficiency:
The flat design allows for space-efficient connections, making them suitable for tight spaces.
Often preferred in situations with limited room for bulkier ring terminals.
Variety of Sizes:
Like ring terminals, spade terminals come in various sizes to match different wire gauges.
Versatile for multiple applications, especially where space is a consideration.
News & Topics at Hont Cable Ties